Surge Protection Device OBV4
    >> Power-Surge-Protection
Surge Suppressor OBV4 In:40kA Imax:80kA
     
 
Advantage >>

SPD OEM

Products Details >>
 
Product Description
OBV4 series surge protection device (in short: SPD, alias: surge protector, surge arrester) is suitable for TN-S, TN-C-S, TT, IT etc. power supply system of AC 50/60Hz, <380V, and installed on the joint of LPZOA zone or LPZOB and LPZ1 zone, which protects the electric network not shocked by the thunder, it’s designed according to GB18802.1, IEC61643-1, it adopts 35mm standard rail, there is a failure release mounted on the module of surge protection device. When the SPD fails in breakdown for over-heat and over-current, the failure release will help electric device separate from the power supply system and give the indication signal, green means normal, red means abnormal, it’s also could be replaced for the module when has operating voltage.
Model and Meaning
 
Application Scope and Installation Position
OBV4 series surge protection devices is suitable for B grade lightning protection, installed on the joint of LPZOA zone or LPZOB and LPZ1 zone, which protects the electric network not shocked by the thunder or surge over voltage. OBV4-60, OBV4-80, OBV4-100 are usually installed in low voltage main distribution box connected to the incoming end of the buildings.
Notice: When you order our goods, please write the model and quantity carefully. For example: OBV4-80/4-385, 8 pieces.
 
Main Technical Parameters
 
OBV4-60
OBV4-80
OBV4-100
Max. Continuous Operating Voltage Uc(V~)
385V
420V
385V
420V
385V
420V
Voltage Protection Level Up(V~)kV
2.0kV
2.5kV
2.0kV
2.5kV
2.5kV
3.0kV
Nominal Discharge Current In (kA)
30kA
40kA
60kA
Max. Discharge Current Imax (kA)
60kA
80kA
100kA
Response Time (ns)
<25 ns
The Cross Section of L/N Line ( mm2)
25-35 mm2
The Cross Section of PE Line ( mm2)
25-35 mm2
Fuse or Switch (A)
32A
63A
63A
Operating Environment (centidegree)
-40OC~+85OC centidegree
Relative Humidity (25 centidegree)
< 95%
Installation
Standard Rail 35mm
Material of Outer Covering
Fiberglass PC
 
Dimension